6,583 research outputs found

    Ion energy measurements on MAST using a midplane RFEA

    Full text link
    Ion energy measurements have been made in the scrape off layer of the Mega Amp Spherical Tokamak (MAST) using a midplane retarding field energy analyser (RFEA) in H-mode plasmas during the inter-edge localised mode (ELM) period and during type I and type III ELMs. During the inter-ELM period at distances of 3 to 8 cm from the last closed flux surface (LCFS), ion temperatures of 20 to 70 eV have been measured giving an ion to electron temperature ratio of 2 to 7 with a mean of 4. During type III ELMs, an ion temperature of 50 eV has been measured 3 to 6 cm from the LCFS which decreases to 30 eV at distances 11 to 16 cm from the LCFS. During type I ELMs, an ion temperature of 40 eV has been measured at a distance of 10 to 15 cm from the LCFS.Comment: 15 pages, 5 figure

    Thermalization of Squeezed States

    Full text link
    Starting with a thermal squeezed state defined as a conventional thermal state based on an appropriate hamiltonian, we show how an important physical property, the signal-to-noise ratio, is degraded, and propose a simple model of thermalization (Kraus thermalization).Comment: 7 pages, 1 table, 1 figure. Presented at ICSSUR 2005, Besancon, Franc

    QT peak prolongation predicts cardiac death following stroke

    Get PDF
    Cardiac death has been linked in many populations to prolongation of the QT interval (QTe). However, basic science research suggested that the best estimate of the time point when repolarisation begins is near the T-wave peak. We found QT peak (QTp) was longer in hypertensive subjects with LVH. A prolonged “depolarisation” phase, rather than “repolarisation” (T peak to T end) might therefore account for the higher incidence of cardiac death linked to long QT. Hypothesis: We have tested the hypothesis that QT peak (QTp) prolongation predicts cardiac death in stroke survivors. Methods and Results: ECGs were recorded from 296 stroke survivors (152 male), mean age 67.2 (SD 11.6) approximately 1 year after the event. Their mean blood pressure was 152/88 mmHg (SD 29/15mmHg). These ECGs were digitised by one observer who was blinded to patient outcome. The patients were followed up for a median of 3.3 years. The primary endpoint was cardiac death. A prolonged heart rate corrected QT peak (QTpc) of lead I carried the highest relative risk of death from all cause as well as cardiac death, when compared with the other more conventional QT indices. In multivariate analyses, when adjusted for conventional risk factors of atherosclerosis, a prolonged QTpc of lead I was still associated with a 3-fold increased risk of cardiac death. (adjusted relative risk 3.0 [95% CI 1.1 - 8.5], p=0.037). Conclusion: QT peak prolongation in lead I predicts cardiac death after strok

    A component modes projection and assembly model reduction methodology for articulated, multi-flexible body structures

    Get PDF
    A two-stage model reduction methodology, combining the classical Component Mode Synthesis (CMS) method and the newly developed Enhanced Projection and Assembly (EP&A) method, is proposed in this research. The first stage of this methodology, called the COmponent Modes Projection and Assembly model REduction (COMPARE) method, involves the generation of CMS mode sets, such as the MacNeal-Rubin mode sets. These mode sets are then used to reduce the order of each component model in the Rayleigh-Ritz sense. The resultant component models are then combined to generate reduced-order system models at various system configurations. A composite mode set which retains important system modes at all system configurations is then selected from these reduced-order system models. In the second stage, the EP&A model reduction method is employed to reduce further the order of the system model generated in the first stage. The effectiveness of the COMPARE methodology has been successfully demonstrated on a high-order, finite-element model of the cruise-configured Galileo spacecraft

    Learning preferences for large scale multi-label problems

    Get PDF
    Despite that the majority of machine learning approaches aim to solve binary classification problems, several real-world applications require specialized algorithms able to handle many different classes, as in the case of single-label multi-class and multi-label classification problems. The Label Ranking framework is a generalization of the above mentioned settings, which aims to map instances from the input space to a total order over the set of possible labels. However, generally these algorithms are more complex than binary ones, and their application on large-scale datasets could be untractable. The main contribution of this work is the proposal of a novel general online preference-based label ranking framework. The proposed framework is able to solve binary, multi-class, multi-label and ranking problems. A comparison with other baselines has been performed, showing effectiveness and efficiency in a real-world large-scale multi-label task

    Overview of physics results from MAST towards ITER/DEMO and the MAST Upgrade

    Get PDF
    New diagnostic, modelling and plant capability on the Mega Ampere Spherical Tokamak (MAST) have delivered important results in key areas for ITER/DEMO and the upcoming MAST Upgrade, a step towards future ST devices on the path to fusion currently under procurement. Micro-stability analysis of the pedestal highlights the potential roles of micro-tearing modes and kinetic ballooning modes for the pedestal formation. Mitigation of edge localized modes (ELM) using resonant magnetic perturbation has been demonstrated for toroidal mode numbers n = 3, 4, 6 with an ELM frequency increase by up to a factor of 9, compatible with pellet fuelling. The peak heat flux of mitigated and natural ELMs follows the same linear trend with ELM energy loss and the first ELM-resolved T-i measurements in the divertor region are shown. Measurements of flow shear and turbulence dynamics during L-H transitions show filaments erupting from the plasma edge whilst the full flow shear is still present. Off-axis neutral beam injection helps to strongly reduce the redistribution of fast-ions due to fishbone modes when compared to on-axis injection. Low-k ion-scale turbulence has been measured in L-mode and compared to global gyro-kinetic simulations. A statistical analysis of principal turbulence time scales shows them to be of comparable magnitude and reasonably correlated with turbulence decorrelation time. T-e inside the island of a neoclassical tearing mode allow the analysis of the island evolution without assuming specific models for the heat flux. Other results include the discrepancy of the current profile evolution during the current ramp-up with solutions of the poloidal field diffusion equation, studies of the anomalous Doppler resonance compressional Alfven eigenmodes, disruption mitigation studies and modelling of the new divertor design for MAST Upgrade. The novel 3D electron Bernstein synthetic imaging shows promising first data sensitive to the edge current profile and flows

    Towards understanding the clinical significance of QT peak prolongation: a novel marker of myocardial ischemia independently demonstrated in two prospective studies

    Get PDF
    Background: QT peak prolongation identified patients at risk of death or non-fatal MI. We tested the hypothesis that QT peak prolongation might be associated with significant myocardial ischaemia in two separate cohorts to see how widely applicable the concept was. Methods and Results: In the first study, 134 stroke survivors were prospectively recruited and had 12-lead ECGs and Nuclear myocardial perfusion scanning. QT peak was measured in lead I of a 12-lead ECG and heart rate corrected by Bazett’s formula (QTpc). QTpc prolongation to 360ms or more was 92% specific at diagnosing severe myocardial ischaemia. This hypothesis-generating study led us to perform a second prospective study in a different cohort of patients who were referred for dobutamine stress echocardiography. 13 of 102 patients had significant myocardial ischaemia. Significant myocardial ischaemia was associated with QT peak prolongation at rest (mean 354ms, 95% CI 341-367ms, compared with mean 332ms, 95% CI 327-337ms in those without significant ischaemia; p=0.002). QT peak prolongation to 360ms or more was 88% specific at diagnosing significant myocardial ischaemia in the stress echocardiography study. QT peak prolongation to 360ms or more was associated with over 4-fold increase odds ratio of significant myocardial ischaemia. The Mantel- Haenszel Common Odds Ratio Estimate=4.4, 95% CI=1.2-16.0, p=0.023. Conclusion: QT peak (QTpc) prolongation to 360ms or more should make us suspect the presence of significant myocardial ischaemia. Such patients merit further investigations for potentially treatable ischaemic heart disease to reduce their risk of subsequent death or non-fatal MI

    Optical clocks based on ultra-narrow three-photon resonances in alkaline earth atoms

    Full text link
    A sharp resonance line that appears in three-photon transitions between the 1S0^{1}S_{0} and 3P0^{3}P_{0} states of alkaline earth and Yb atoms is proposed as an optical frequency standard. This proposal permits the use of the even isotopes, in which the clock transition is narrower than in proposed clocks using the odd isotopes and the energy interval is not affected by external magnetic fields or the polarization of trapping light. The method has the unique feature that the width and rate of the clock transition can be continuously adjusted from the MHzMHz level to sub-mHzmHz without loss of signal amplitude by varying the intensities of the three optical beams. Doppler and recoil effects can be eliminated by proper alignment of the three optical beams or by point confinement in a lattice trap. The three beams can be mixed to produce the optical frequency corresponding to the 3P0^{3}P_{0} - 1S0^{1}S_{0} clock interval.Comment: 10 pages, 4 figures, submitted to PR

    Bioinformatics tools in predictive ecology: Applications to fisheries

    Get PDF
    This article is made available throught the Brunel Open Access Publishing Fund - Copygith @ 2012 Tucker et al.There has been a huge effort in the advancement of analytical techniques for molecular biological data over the past decade. This has led to many novel algorithms that are specialized to deal with data associated with biological phenomena, such as gene expression and protein interactions. In contrast, ecological data analysis has remained focused to some degree on off-the-shelf statistical techniques though this is starting to change with the adoption of state-of-the-art methods, where few assumptions can be made about the data and a more explorative approach is required, for example, through the use of Bayesian networks. In this paper, some novel bioinformatics tools for microarray data are discussed along with their ‘crossover potential’ with an application to fisheries data. In particular, a focus is made on the development of models that identify functionally equivalent species in different fish communities with the aim of predicting functional collapse
    corecore